MAGYAR
PRODUCTS
Enquiry Support About Us Contact Us Why Us? Applications
Preclinical research
World Precision Instruments
Human Diagnostic
Biostatistics

Cardiological Days of Debrecen

3th - 6th Mar, 2010

Debrecen, Hungary

BioEurope Spring

8th - 10th Mar, 2010

Barcelona, Spain

Congress of the Hungarian Diabetes Association

22th - 25th Apr, 2010

Tihany, Hungary

Congress of the Hungarian Society of Cardiology

5th - 8th May, 2010

Balatonfüred, Hungary

Heart Failure Congress 2010

29th May - 1th Jun, 2010

Berlin, Germany

Heart Failure Congress 2010

29th May - 1th Jun, 2010

Berlin, Germany

Joint Congress of the Hungarian Physiological Society and Hungarian Society for Experimental and Clinical Pharmacology

16th - 18th Jun, 2010

Szeged, Hungary

7th FENS Forum of European Neurosience

3th - 7th Jul, 2010

Amsterdam, The Netherlands

WorldPharma 2010

17th - 23th Jul, 2010

Copenhagen, Denmark

Congress of the Hungarian Surgical Society

8th - 11th Sep, 2010

Siófok, Hungary

6th Croatian Congress of Pharmacology

15th - 18th Sep, 2010

Opatija, Croatia

Hungarian Paediatrician Congress

23th - 25th Sep, 2010

Esztergom, Hungary

Cardiological Days of Debrecen

3th - 6th Mar, 2010

Debrecen, Hungary

BioEurope Spring

8th - 10th Mar, 2010

Barcelona, Spain

Congress of the Hungarian Diabetes Association

22th - 25th Apr, 2010

Tihany, Hungary

Congress of the Hungarian Society of Cardiology

5th - 8th May, 2010

Balatonfüred, Hungary

Heart Failure Congress 2010

29th May - 1th Jun, 2010

Berlin, Germany

Heart Failure Congress 2010

29th May - 1th Jun, 2010

Berlin, Germany

Joint Congress of the Hungarian Physiological Society and Hungarian Society for Experimental and Clinical Pharmacology

16th - 18th Jun, 2010

Szeged, Hungary

7th FENS Forum of European Neurosience

3th - 7th Jul, 2010

Amsterdam, The Netherlands

WorldPharma 2010

17th - 23th Jul, 2010

Copenhagen, Denmark

Congress of the Hungarian Surgical Society

8th - 11th Sep, 2010

Siófok, Hungary

6th Croatian Congress of Pharmacology

15th - 18th Sep, 2010

Opatija, Croatia

Hungarian Paediatrician Congress

23th - 25th Sep, 2010

Esztergom, Hungary

More events »
Certificate

Whole Heart Perfusion System

GENERAL OVERVIEW

Experimetira Ltd. Has a long term experiences in the fields of equipments for small mammalian's organ perfusion.

  • The basic organ perfusion system is suitable for "in-vitro" investigation of heart, kidney, liver or gut (mesenteric bed) of small animals, such as rat, hamster, guinea pig and rabbit. The system is available for the adjustment of generally used basic methods.
  • For isolated heart preparations variety of small mammalian species are used. Most of the preparations are rat hearts, which are placed in wide range of non-working Langendorff devices, where the coronaries are perfused retrograde at closed aortic valve. Another commonly used model is the working heart preparation, which was introduced by Neely et. al. in 1967.
Generally in Experimetria’s organ perfusion system constant pressure is kept by hydrostatic pressure of a buffer column, whereas constant flow could be maintained by a precision roller pump. The pressure can be adjusted with the help of an inner glass tube, which is movable up and down and therefore more or less solution can be kept in the buffer column. To keep the perfusion solution always on the same level a small reeling pump is included in the set-up. which is another unique feature in these set-ups. The two-way Teflon taps are designed and developed by Experimetria Ltd. These small but very handy units help scientists to drive the perfusion solution easily without having a silicon tube maze on the set-ups even in case of three columns are attached to the systems. Because of these taps are made from Teflon no lubricant material is needed therefore contamination can be avoided. The inner side of the tap is designed on such a way that during opening the perfusion solution reaches the maximum flow almost immediately. To avoid cooling down of the perfusion solution the systems are equipped with pre-heater units on various places and the perfusion solution's temperature is measured just in front of the organ. The systems are water-jacketed and they are only complete if a temperature control unit is added to them and the temperature is maintained by circulating water bath.
All of these systems are built up on a laboratory table in which a stainless steel sink is built in. Systems can be equipped with electronic stimulator, stimulator electrodes, flow meter, flow probe, suitable electronic amplifiers and sensors. Data acquisition software and hardware system is also available as well as low cost and high quality circulating water bath.

LF-01-LF1 and LF-02-LF2 Perfusion systems for isolated, small mammalian hearts according to Langendorff

More details »

LF-03-WHN Isolated working heart systems according to Neely

More details »

LF-04-MINI System for isolated, perfused heart (Compact Langendorff) for ischemia reperfusion studies

More details »

BACK TO TOP
Copyright © 1982-2009 Experimetria Ltd. All Rights Reserved |Privacy & Cookies |Terms of Use |Sitemap