Complex biostatistical solutions from AdWare Research Ltd., the partner company of Experimetria. Preparation of biostatistical evaluation, completion of audits according to pharmaceutical industry quality assurance as an independent organization together with training and consultancy.
More details »
|
|
Congress of the Hungarian Society of Cardiology 5th - 8th May, 2010 Balatonfüred, Hungary Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Romanian Physiological Congress 2th - 5th Jun, 2010 Baile Felix Joint Congress of the Hungarian Physiological Society and Hungarian Society for Experimental and Clinical Pharmacology 16th - 18th Jun, 2010 Szeged, Hungary 7th FENS Forum of European Neurosience 3th - 7th Jul, 2010 Amsterdam, The Netherlands Congress of the Hungarian Surgical Society 8th - 11th Sep, 2010 Siófok, Hungary 60th Czech-Slovak Pharmacological Days 15th - 17th Sep, 2010 Hradec Králové, Czech Republic 6th Croatian Congress of Pharmacology 15th - 18th Sep, 2010 Opatija, Croatia Congress of the Hungarian Society of Cardiology 5th - 8th May, 2010 Balatonfüred, Hungary Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Romanian Physiological Congress 2th - 5th Jun, 2010 Baile Felix Joint Congress of the Hungarian Physiological Society and Hungarian Society for Experimental and Clinical Pharmacology 16th - 18th Jun, 2010 Szeged, Hungary 7th FENS Forum of European Neurosience 3th - 7th Jul, 2010 Amsterdam, The Netherlands Congress of the Hungarian Surgical Society 8th - 11th Sep, 2010 Siófok, Hungary 60th Czech-Slovak Pharmacological Days 15th - 17th Sep, 2010 Hradec Králové, Czech Republic 6th Croatian Congress of Pharmacology 15th - 18th Sep, 2010 Opatija, Croatia More events »
|
| Certificate |
 |
|
AMP-10-INTS Intracellular amplifier system for measurement of heart intracellular action potential using KCL glass electrodes
Experimetria intracellular workstation (EXP-INTS) is a ready-for-work solution those who are looking for a high quality set-up with a simple, easy to use design to measure QT, evoked potentials and single cell membrane potentials in “ in-vitro” conditions together with changes of force displacement. The system is also equipped with a high performance isolated stimulator-amplifier unit. Circulating water bath, data acquisition system, Faraday cage and other accessories are available at Experimetria Ltd.
The intracellular linear (INT) amplifier is designed to measure QT, evoked potentials and single cell membrane potentials in “in-vitro” conditions. The amplifier exhibits low noise, high input resistance and low input capacitance. It consists of two items, an INT amplifier and a pre-amplifier (head-stage). The task of preamplifier is to enable the impedance connection between the electrode and the end-amplifiers (x1 amplification). The INT amplifier provides function checks (resistance measurement, capacitance compensation), the 10-fold amplification and it helps monitoring the insertion of the electrode with the built-in sound generator. The 3-digit LED display enables to read the mV values during the entire experiment (except of the resistance value).
Parameters of INT amplifier Input resistance: 10 kΩ Amplification: 1x, 10x Bucking: ±300 mV Impedance measurement: 0-100 MΩ Calibration signal: 200 Hz square wave Insertation monitor: audio Display: 5-digit LED
Parameters of pre-amplifier Input resistance: 10 Ω Amplification: X1 Input capacitance: 0-25 pF (compensated) Housing: aluminum Cable length: 70 mm O.D.: 15 mm Cable: shielded Microelectrode holder connector: standard 2mm I.D. (i.e. Clark type, WPI type, etc.)
The strain gauge (SG) amplifier has been designed to receive and amplify signals based on resistance changes of force-, displacement- and pressure- transducers. The SG unit is highly flexible based on its three different built-in filter, high gain maximum (250.000), adjustable output level with potentiometer (0-100%) and LED bar for visual control of changes.
Parameters Bridge supply voltage: 2V, 5V, 7V, gradual, internally selectable Standard adjustment: 2V or 5V Gain: adjustment continuously by potentiometer in the range of 2000- 250.000 Calibration: by potentiometer according to passed sensor Analogue indication: 2 LED monitoring of bridge and a LED bar for monitoring output Low pass filter: three position of filter switch for 3, 10 and 40 Hz Input: 25 kΩ symmetrical, maximum ±5V Output: Impedance: 100 Ω, full scale between 0±5V can be continuously adjusted. Output is a voltage generator type.
The isolated stimulator (ISO) amplifier is designed for simple stimulating or organs or tissues, triggering of evoked potential. It can be used in both “in-vivio” and “in-vitro” conditions of animal experiments as voltage or current generator. The output level is adjustable between 0-100% with a potentiometer and the polarity is selectable for any type of impulses.
Parameters Voltage range: 10 V 100 V Current ranges: 1 mA, 100 mA, 150 mA
|