Complex biostatistical solutions from AdWare Research Ltd., the partner company of Experimetria. Preparation of biostatistical evaluation, completion of audits according to pharmaceutical industry quality assurance as an independent organization together with training and consultancy.
More details »
|
|
Congress of the Hungarian Society of Cardiology 5th - 8th May, 2010 Balatonfüred, Hungary Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Romanian Physiological Congress 2th - 5th Jun, 2010 Baile Felix Joint Congress of the Hungarian Physiological Society and Hungarian Society for Experimental and Clinical Pharmacology 16th - 18th Jun, 2010 Szeged, Hungary 7th FENS Forum of European Neurosience 3th - 7th Jul, 2010 Amsterdam, The Netherlands Congress of the Hungarian Surgical Society 8th - 11th Sep, 2010 Siófok, Hungary 60th Czech-Slovak Pharmacological Days 15th - 17th Sep, 2010 Hradec Králové, Czech Republic 6th Croatian Congress of Pharmacology 15th - 18th Sep, 2010 Opatija, Croatia Congress of the Hungarian Society of Cardiology 5th - 8th May, 2010 Balatonfüred, Hungary Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Heart Failure Congress 2010 29th May - 1th Jun, 2010 Berlin, Germany Romanian Physiological Congress 2th - 5th Jun, 2010 Baile Felix Joint Congress of the Hungarian Physiological Society and Hungarian Society for Experimental and Clinical Pharmacology 16th - 18th Jun, 2010 Szeged, Hungary 7th FENS Forum of European Neurosience 3th - 7th Jul, 2010 Amsterdam, The Netherlands Congress of the Hungarian Surgical Society 8th - 11th Sep, 2010 Siófok, Hungary 60th Czech-Slovak Pharmacological Days 15th - 17th Sep, 2010 Hradec Králové, Czech Republic 6th Croatian Congress of Pharmacology 15th - 18th Sep, 2010 Opatija, Croatia More events »
|
| Certificate |
 |
|
LF-03-WHN Isolated working heart systems according to Neely
- for small mammalian hearts (mouse, rat, hamster, rabbit)
- working (Neely) and non-working (Langendorff) options in one device
- pacing possibility
- control of LVDP, coronary flow and cardiac output by varying the left atrial filling pressure and the hydrostatic pressure in the aorta
- measurement of heart rate, atrial and ventricular pressure, cardiac output
- ports for drug administration
- ports for sensor connections
- tissue can be quickly frozen for biochemical investigations
The Neely type working heart model is preferred in such cases, when achieving a higher level of mechanical activity and measurement of external work performance is necessary. Experimetria Neely type working heart perfusion device is the combination of classical Langendorff (non-working) and Neely type (working) options. As a new development for all heart perfusion setups a special MAP sensor is available. Dimensions:Width: 600 mm, length: 800 mm, height: 2550 mm, weight: 80 kg
|