Complex biostatistical solutions from AdWare Research Ltd., the partner company of Experimetria. Preparation of biostatistical evaluation, completion of audits according to pharmaceutical industry quality assurance as an independent organization together with training and consultancy.
More details »
|
|
13th Congress of the Hungarian Neuroscience Society 20th - 22th Jan, 2011 Budapest, Hungary Physiological Days 9th - 11th Feb, 2011 Bratsilava, Slovak Republic Diabetes Meeting 14th - 16th Apr, 2011 Tihany, Hungary Romanian Physiological Congress 26th - 28th May, 2011 Targu Mures FAME 2011 8th - 11th Jun, 2011 Pécs, Hungary 8th IBRO World Congress of Neuroscience 14th - 18th Jul, 2011 Florence, Italy ESC Congress 2011 27th - 31th Aug, 2011 Paris, France 10th International Congress of the Polish Neuroscience Society 21th - 24th Sep, 2011 Lodz, Poland 13th Congress of the Hungarian Neuroscience Society 20th - 22th Jan, 2011 Budapest, Hungary Physiological Days 9th - 11th Feb, 2011 Bratsilava, Slovak Republic Diabetes Meeting 14th - 16th Apr, 2011 Tihany, Hungary Romanian Physiological Congress 26th - 28th May, 2011 Targu Mures FAME 2011 8th - 11th Jun, 2011 Pécs, Hungary 8th IBRO World Congress of Neuroscience 14th - 18th Jul, 2011 Florence, Italy ESC Congress 2011 27th - 31th Aug, 2011 Paris, France 10th International Congress of the Polish Neuroscience Society 21th - 24th Sep, 2011 Lodz, Poland More events »
|
| Certificate |
 |
|
LF-11-LF1 and LF-12-LF2 Perfusion systems for isolated, small mammalian hearts according to Langendorff
- retrograde perfusion of isolated heart of mouse rat, guinea pig, hamster, rabbit
- constant pressure or constant flow mode application on the same devices
- equipped with two buffer columns for using different solutions
- aortic pressure up to 120 mmHg
- ports for measurement of pressure, flow, temperature surface potential and for drug injection/infusion
- continuous filling of buffer columns with a pump
- continuous carbogen bubbling
- water jacked system
This basic Langendorff system is suitable for "in-vitro" investigation of the heart of small animals, such as rat, hamster, guinea pig and rabbit. The system is available for the adjustment of generally used basic methods with the help of supplementary units. Devices are available for using constant pressure or constant flow. The system is also equipped with latex balloon and spindle syringe for LVP measurement. As a new development for all heart perfusion setups a special MAP sensor is available. Dimensions:Width: 600mm, length: 800mm, height: 2500mm, weight: 80kg
|