13th Congress of the Hungarian Neuroscience Society 20th - 22th Jan, 2011 Budapest, Hungary Physiological Days 9th - 11th Feb, 2011 Bratsilava, Slovak Republic Diabetes Meeting 14th - 16th Apr, 2011 Tihany, Hungary Romanian Physiological Congress 26th - 28th May, 2011 Targu Mures FAME 2011 8th - 11th Jun, 2011 Pécs, Hungary 8th IBRO World Congress of Neuroscience 14th - 18th Jul, 2011 Florence, Italy ESC Congress 2011 27th - 31th Aug, 2011 Paris, France 10th International Congress of the Polish Neuroscience Society 21th - 24th Sep, 2011 Lodz, Poland 13th Congress of the Hungarian Neuroscience Society 20th - 22th Jan, 2011 Budapest, Hungary Physiological Days 9th - 11th Feb, 2011 Bratsilava, Slovak Republic Diabetes Meeting 14th - 16th Apr, 2011 Tihany, Hungary Romanian Physiological Congress 26th - 28th May, 2011 Targu Mures FAME 2011 8th - 11th Jun, 2011 Pécs, Hungary 8th IBRO World Congress of Neuroscience 14th - 18th Jul, 2011 Florence, Italy ESC Congress 2011 27th - 31th Aug, 2011 Paris, France 10th International Congress of the Polish Neuroscience Society 21th - 24th Sep, 2011 Lodz, Poland More events »
|
| Certificate |
 |
|
AMP-11-ECGP 12 channel electrocardiograph amplifier (Polygraph)
Main features
- 12 lead ECG measurement parallely
- Hifi diagnostic mode
- Filter between 0.05 – 500Hz
- Convenient back panel for in- and output connectors
- Defibrillation protected
This 12 lead ECG Polygraph has been designed to meet the demanding requirements of the pre-clinical research community. The amplifier accurately conditions up to twelve simultaneous ECG leads. The leads are: I, II, III, aVR, aVL, aVF (derived from Einthoven’s triangle) and six V leads (referenced to Wilson’s central terminal). The "RL" (Right Leg) is driven by a signal derived from either Wilson’s central terminal or Iso-common. The patient cables are connected through an industry standard ten-lead ECG cable.
Parameters Gain: 1000x, calibrated Built-in reference level: GND; 1 V (for setting the signal processing unit) Function: I-II-III
Input: (balanced) Impedance: 1 MΩ parallel 1 nF L, R, F, N signal cables, over voltage protection with diodes
Output: (unbalanced) I, II, III, aVR, aVF, aVL, V1-V6 outputs Over voltage: ± 10 V
Calibrated signal level: + 1 V = 1 V with reagrd to input
Accessories: function and power supply cable(s), operation instruction
|