Complex biostatistical solutions from AdWare Research Ltd., the partner company of Experimetria. Preparation of biostatistical evaluation, completion of audits according to pharmaceutical industry quality assurance as an independent organization together with training and consultancy.
More details »
|
|
13th Congress of the Hungarian Neuroscience Society 20th - 22th Jan, 2011 Budapest, Hungary Physiological Days 9th - 11th Feb, 2011 Bratsilava, Slovak Republic Diabetes Meeting 14th - 16th Apr, 2011 Tihany, Hungary Romanian Physiological Congress 26th - 28th May, 2011 Targu Mures FAME 2011 8th - 11th Jun, 2011 Pécs, Hungary 8th IBRO World Congress of Neuroscience 14th - 18th Jul, 2011 Florence, Italy ESC Congress 2011 27th - 31th Aug, 2011 Paris, France 10th International Congress of the Polish Neuroscience Society 21th - 24th Sep, 2011 Lodz, Poland 13th Congress of the Hungarian Neuroscience Society 20th - 22th Jan, 2011 Budapest, Hungary Physiological Days 9th - 11th Feb, 2011 Bratsilava, Slovak Republic Diabetes Meeting 14th - 16th Apr, 2011 Tihany, Hungary Romanian Physiological Congress 26th - 28th May, 2011 Targu Mures FAME 2011 8th - 11th Jun, 2011 Pécs, Hungary 8th IBRO World Congress of Neuroscience 14th - 18th Jul, 2011 Florence, Italy ESC Congress 2011 27th - 31th Aug, 2011 Paris, France 10th International Congress of the Polish Neuroscience Society 21th - 24th Sep, 2011 Lodz, Poland More events »
|
| Certificate |
 |
|
AMP-04 Bioamplifier with head stage for general purposes (EEG, EMG, ECG, EP, INT)
Main features
- high and low pass filters
- for evoked or spontaneous tissue action potentials
- selectable gain
- preamplifier for mono-, and bipolar recording
- very low noise
- high input impedance
- built-in calibration
- AMP-04-1 one channel set-up
- AMP-04-2 two channel set-up
- AMP-04-3 four channel set-up
ParametersGain: 104, 103, 102 calibrated, together with input preamplifier Built-in filtering: High cut filter (Hz): OFF, 20K, 10K, 2K, 1K, 500, 300, 100, 50, 30 Low cut filter (Hz): DC, 0.05, 0.1, 0.5, 1, 5, 10, 50, 100 Built-in references levels: GND, 1 V (for setting the signal processing unit) Notch filter: 50 Hz (optionally 60 Hz) DC offset: ±2V on the output Block: grounds amplifier input Preamplifier unitInput impedance: 10 MΩ Balanced, unbalanced switch able CMMR > 80 dB Noise: (0.5, 70Hz) < 1.5 mV with regard to input Output Unbalanced Output impedance: 100Ω Protected against short circuit Overvoltage: ±10V Accessories: function cables, subject cables, operating instructions
|